MIL-DTL-3702F
6.2 Acquisition requirements. Acquisition documents should specify the following:
a. Title, number, and date of this specification.
b. Title, number, and date of the applicable specification sheet (see 3.1)
c.
d. Shielding, if other than specified (see 3.2.5).
e. Cable length, if other than as specified (see 3.3.7.2).
f.
If responsibility for inspection, inspection equipment, or inspection facilities are other than as
specified (see 4.1).
g. If inspection conditions will be other than as specified (see 4.3).
h. If control test sampling will be other than as specified (see 4.6).
Selection of applicable levels of preservation, packaging, packing, and marking (see 5.1).
i.
j.
If age of the cable from a bulk purchaser will be other than specified (see 3.6).
k.
6.3 Qualification. With respect to products requiring qualification, awards will be made only for
products which are, at the time of award of contract, qualified for inclusion in QPDSIS-3702. whether or
not such products have actually been so listed by that date. The attention of the contractors is called to
these requirements, and manufacturers are urged to arrange to have the products that they propose to
offer to the Federal Government tested for qualification in order that they may be eligible to be awarded
contracts or orders for the products covered by this specification. Information pertaining to qualification of
products may be obtained from DLA Land and Maritime, ATTN: VQ, P.O. Box 3990 East Broad Street,
Columbus, OH, 43218-3990. An online listing of products qualified to this specification may be found in
the Qualified Products Database (QPD) at https://assist.daps.dla.mil.
6.4 Extension of qualification. Qualification of cable of a given type designation (see 1.2.1) submitted
by a manufacturer will serve to qualify other cable of similar construction by the same manufacturer.
Extension of qualification will apply as listed in table XI.
TABLE XI. Qualification extensions.
Qualified sample
Qualified by extension
Type of shielding (see 1.2.1.2).
S
U
L
L
Temperature limit (see 1.2.1.4).
M
M
H
H
C (19 strands)
C (19 strands) and S (7 strands)
C (19 strands), C (37 strands),
Conductor material (see 1.2.1.5).
C (37 strands)
and S (7 strands)
S (7 strands)
S (7 strands only)
5
5 and 7
Cable diameter (see 1.2.1.3).
7
7 only
24