MIL-DTL-3432J
TABLE XII. Inspection sample.
1/
Production lot size
Sample size
2 to 8
2
9 to 15
3
16 to 25
5
26 to 50
8
51 to 90
13
91 to 150
20
151 to 280
32
281 to 500
50
501 to 1200
80
1201 to 3200
125
3201 to 10000
200
10001 to 35000
315
1/ Lot size will be based on number of reels, spools, or coils of product.
4.6.1.4 Selection of sample units. Sample units for inspection shall be taken from each unit of product. A sample
unit is defined as a length of cable drawn from a unit of product.
4.6.1.5 Test specimen. A test specimen may be the entire sample unit (length of finished cable) or any portion or
any portion of the sample unit that is to be tested.
4.6.1.6 Group A inspection. Group A inspection shall consist of the inspections specified in table XIII, in the order
shown.
4.6.1.6.1 Group A acceptance. Each sample selected in accordance with 4.6.1.4 shall be examined to determine
conformance with the requirements in table XIII. If one or more defects are found in the inspection sample, the
production lot shall be rejected and shall not be supplied to this specification.
19
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business