MIL-DTL-13777/5D
TABLE II. Design data Continued.
DATA DESIGN
3/
3/ 10/
3/
Type designation
371327S
371417S
391115S
Figure number
8
9
10
Total wires
37
37
39
3/ 11/
8/
Number of conductors & AWG #
21/#18
10/#18S*
6/#14
37/#18
39/#18
Insulation
Minimum average thickness
0.015"
0.015"
0.015"
Spark test voltage
3000
3000
3000
Inspection test voltage
1500
1500
1500
Cabling
Layer 1
Filler
(a) Number of wires
4
2 pr tw/sh
3/
(b) AWG #
#18S
#18
(c) Maximum lay
3.00"
2/
Layer 2
(a) Number of wires
6
6
14
3/
(b) AWG #
#18S
#14
#18
#18
(c) Maximum lay
9.75"
5.00"
Layer 3
(a) Number of wires
21
21
(b) AWG #
#18
#18
#18
(c) Maximum lay
9.75"
6.00"
Sheath
Number of layers
2
2
2
Total thickness, minimum
0.125"
0.156"
0.109"
Minimum OD cable
1.297"
1.472"
1.100"
Maximum OD cable
1.357"
1.562"
1.130"
Maximum weight (lbs/1000ft.)
780
See notes at end of table.