MIL-DTL-13777/5D
TABLE II. Design data Continued.
DESIGN DATA
3/
Type designation
471374S
Figure number
16
Total wires
47
3/
3/
3/
Number of conductors & AWG #
41/#18
1/#18S
3/#14S
1/#12
1/#12S
Insulation
Minimum average thickness
0.015"
0.015"
0.015"
0.020"
0.020"
Spark test voltage
3000
3000
3000
4000
4000
Inspection test voltage
1500
1500
1500
2000
2000
Cabling
Layer 1
(a) Number of wires
1
3
1
1
3/
3/
3/
(b) AWG #
#18S
#14S
#12
#12S
(c) Maximum lay
Layer 2
(a) Number of wires
18
(b) AWG #
#18
(c) Maximum lay
Layer 3
(a) Number of wires
23
(b) AWG #
#18
(c) Maximum lay
Sheath
Number of layers
2
Total thickness minimum
0.125"
Minimum OD cable
1.344"
Maximum OD cable
1.404"
See notes at end of table.