MIL-DTL-13777/5D
TABLE II. Design data.
DESIGN DATA
3/
Type designation
341273S
360860*
S361055*
Figure number
1
2
2
Total wires
34
36
36
1/
2/
Number of conductors & AWG #
23/#18
6/#18S
5/#16
36/#20
36/#18
Insulation
Minimum average thickness
0.015"
0.015"
0.015"
Spark test voltage
3000
3000
3000
Inspection test voltage
1500
1500
1500
Cabling
Layer 1
Filler
Filler
Filler
Layer 2
(a) Number of wires
8
6
6
6
2/
(b) AWG #
#18
#18S
#20
#18
(c) Maximum lay
Layer 3
(a) Number of wires
15
5
12
12
(b) AWG #
#18
#16
#20
#18
(c) Maximum lay
Layer 4
(a) Number of wires
18
18
(b) AWG #
#20
#18
(c) Maximum lay
7.0"
Sheath
Number of layers
2
1
2
Total thickness minimum
0.140"
0.080"
0.117"
Minimum OD cable
1.248"
0.835"
1.025"
Maximum OD cable
1.318"
0.885"
1.085"
See notes at end of table.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business