MIL-DTL-13777/5D
TABLE II. Design data Continued.
DESIGN DATA
Type designation
371193S
Figure number
6
Total wires
37
Number of conductors & AWG #
29/#18
2/#18S
6/#14
Insulation
Minimum average thickness
0.015"
Spark test voltage
3000
Inspection test voltage
1500
Cabling
Layer 1
Filler
Layer 2
(a) Number of wires
3
2
1
(b) AWG #
#18
#18S
#14
(c) Maximum lay
Layer 3
(a) Number of wires
7
5
(b) AWG #
#18
#14
(c) Maximum lay
Layer 4
(a) Number of wires
19
(b) AWG #
#18
(c) Maximum lay
Sheath
Number of layers
2
Total thickness minimum
0.125"
Minimum OD cable
1.163"
Maximum OD cable
1.223"
See notes at end of table.