MIL-DTL-13777/5D
TABLE II. Design data Continued.
DESIGN DATA
3/
Type designation
361420S
Figure number
3
Total wires
36
3/ 4/
3/
Number of conductors & AWG #
17/#18
13/#18S
5/#16
1/#16S
Insulation
Minimum average thickness
0.015"
Spark test voltage
3000
Inspection test voltage
1500
Cabling
Layer 1
Filler
Layer 2
(a) Number of wires
13
1
3/
3/
(b) AWG #
#18S
#16S
(c) Maximum lay
Layer 3
(a) Number of wires
17
5
(b) AWG #
#18
#16
(c) Maximum lay
Layer 4
(a) Number of wires
(b) AWG #
(c) Maximum lay
Sheath
Number of layers
2
Total thickness minimum
0.140"
Minimum OD cable
1.382"
Maximum OD cable
1.462"
See notes at end of table.