MIL-DTL-3849C
3.3.4 Insulation. The compounds used for insulation shall be of the types specified in the applicable
specification sheets (see 3.1).
3.3.4.1 Insulation wall thickness. The minimum wall thickness of the insulation shall be specified in
the applicable specification sheets (see 3.1).
3.3.4.2 Diameter of insulated conductors. The diameter of each insulated conductor shall be as
follows:
Tinsel wire
Diameter of
insulated conductor inches (mm)
(type, MIL-W-3795)
I
.071 to .081 (1.80 to 2.06 mm)
II
.070 to .076 (1.78 to 1.93 mm)
V
.024 to .028 (0.61 to 0.71)
3.3.4.3 Insulation color coding. The color of the insulation shall be in accordance with MIL-STD-104.
The color coding of the individual insulated conductors in a core complement shall be in the following
sequence:
Conductor
Color
number
1
Black
2
White
3
Red
4
Green
Orange
5
3.3.5 Jacket. The compounds used for jacketing shall be of the types specified on the applicable
specification sheets (see 3.1). The jacket shall be black unless other wise specified in the applicable
specification sheet (see 3.1). The jacket shall be smooth and free of surface irregularities.
3.3.5.1 Jacket wall thickness. The jacket wall thickness shall be as specified on the applicable
specification sheet (see 3.1).
3.4 Outside diameter (cable). The outside diameter of the finished cable shall be as specified on the
applicable specification sheet (see 3.1).
3.5 Finished cords. The finished cords shall be in accordance with the requirements of this
specification and the applicable specification sheet (see 3.1).
3.6 Electrical requirements.
3.6.1 Dielectric withstanding voltage. The insulated conductors shall withstand, without breakdown,
an applied voltage of 500 volts DC (350 volts AC rms), when tested as specified in 4.6.2.1.
3.6.2 Insulation resistance. Immediately after the insulated conductors have been subjected to the
dielectric withstanding voltage test, the insulation resistance shall be measured as specified in 4.6.2.2.
The insulation resistance of each insulated conductor shall be not less than the value specified on the
applicable specification sheet (see 3.1).
3.6.3 Continuity. Each conductor of the finished cord shall be continuous when tested as specified in
4.6.2.3.