MIL-DTL-13777/2C
TABLE II. Design data Continued.
Design data
Type designation
150885
150915S
Figure number
17
17
Total wires
15
15
Number of conductors & AWG #
12/#18
3/#12
7/#18
5/#18S
3/#12
Insulation
Min average thickness
0.015"
0.020"
0.015"
0.015"
0.020"
Spark test voltage
3000
4000
3000
3000
4000
Inspection test voltage
1500
2000
1500
1500
2000
Cabling
Layer 1
Filler
Filler
Layer 2
(a) Number of wires
3
3
(b) AWG #
#12
#12
(c) Maximum lay
3.00"
3.00"
Layer 3
(a) Number of wires
12
7
5
(b) AWG #
#18
#18
#18S
(c) Maximum lay
6.00"
6.00"
Sheath
Number of layers
2
2
Total thickness minimum
0.125"
0.120"
Minimum OD cable
0.870"
0.900"
Maximum OD cable
0.900"
0.930"
Maximum weight (lbs. /1000ft.)
490
557
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business