MIL-DTL-13777/2C
TABLE II. Design data.
Design data
Type designation
060410S
060480
060565
Figure number
1
2
2
Total wires
6
6
6
Number of conductors & AWG #
3/#18
3/#18S
6/#18
6/#16
Insulation
Minimum average thickness
0.012"
0.012"
0.015"
0.015"
Spark test voltage
2000
2000
2000
2000
Inspection test voltage
1000
1000
1500
1500
Cabling
Layer 1
Filler
Filler
Filler
Layer 2
(a) Number of wires
3
3
6
6
(b) AWG #
#18
#18S
#18
#16
(c) Maximum lay
5.00"
Sheath
Number of layers
1
1
1
Total thickness min
0.056"
0.070"
0.078"
Minimum OD cable
0.390"
0.460"
0.540"
Maximum OD cable
0.430"
0.500"
0.590"
Design data
Type designation
061530
061805
070590
Figure number
3
4
5
Total wires
6
6
7
Number of conductors & AWG #
4/#18
2/#0
3/#00
3/#5
7/#16
Insulation
Minimum average thickness
0.015"
0.078"
0.075"
0.060"
0.020"
Spark test voltage
3000
7500
7500
3000
4000
Inspection test voltage
1500
2500
5000
1500
2000
Cabling
Layer 1
Filler
Filler
(a) Number of wires
4
2
(b) AWG #
#18
#0
(c) Maximum lay
Layer 2
(a) Number of wires
6
7
(b) AWG #
3/#00
3/#5
#16
(c) Maximum lay
12.00
Sheath
Number of layers
2
2
1
Total thickness min
0.125"
0.188"
0.070"
Minimum OD cable
1.480"
1.760"
0.575"
Maximum OD cable
1.579"
1.850"
0.605"