MIL-DTL-13777/2C
TABLE II. Design data Continued.
Design data
Type designation
070618
070730
070823S
Figure number
5
6
7
Total wires
7
7
7
Number of conductors & AWG #
7/#18
Insulation
Minimum average thickness
0.015"
0.015"
0.020"
0.015"
Spark test voltage
3000
3000
4000
3000
Inspection test voltage
1500
1500
2000
1500
Cabling
Layer 1
Filler
Filler
Filler
Layer 2
(a) Number of wires
7
4
3
(b) AWG #
#18
#16
#12
#18
(c) Maximum lay
4.00"
5.00"
Sheath
Number of layers
1
2
2
Total thickness minimum
0.093"
0.098"
0.109"
Minimum OD cable
0.596"
0.710"
0.798
Maximum OD cable
0.640"
0.750"
0.848"
Design data
Type designation
070930
071090
S080625
080766
Figure number
5
5
8
9
Total wires
7
7
8
8
Number of conductors & AWG #
7/#10
7/#8
8/#18
4/#16
4/#12
Insulation
Minimum average thickness
0.020"
0.025"
0.015"
0.015"
0.020"
Spark test voltage
4000
4000
3000
3000
4000
Inspection test voltage
2000
2000
1500
1500
2000
Cabling
Layer 1
Filler
Filler
Filler
Filler
Layer 2
(a) Number of wires
7
7
8
4
4
(b) AWG #
#10
#8
#18
#16
#12
(c) Maximum lay
6.00"
8.00"
2.50"
Sheath
Number of layers
2
2
1
1
Total thickness minimum
0.125"
0.120"
0.070"
0.080"
Minimum OD cable
0.912"
1.070"
0.610"
0.746"
Maximum OD cable
0.948"
1.110"
0.640"
0.786"
Maximum weight (lbs. /1000ft.)
245
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business