MIL-DTL-13777/2C
TABLE II. Design data Continued.
Design data
Type designation
080840
080918
090540
090675
Figure number
9
10
11
11
Total wires
8
8
9
9
Number of conductors & AWG #
8#12
4/#18
4/#9
9/#20
9/#18
Insulation
Minimum average thickness
0.020"
0.015"
0.040"
0.012"
0.015"
Spark test voltage
4000
3000
4000
3000
3000
Inspection test voltage
2000
1500
2000
1500
1500
Cabling
Layer 1
Filler
Filler
Filler
Filler
Layer 2
(a) Number of wires
8
4
4
9
9
(b) AWG #
#12
#18
#9
#20
#18
(c) Maximum lay
3.5"
3.10"
Sheath
Number of layers
1
2
1
1
Total thickness minimum
0.070"
0.110"
0.063"
0.094"
Minimum OD cable
0.815"
0.888"
0.525"
0.660"
Maximum OD cable
0.865"
0.948"
0.555"
0.690"
Maximum weight (lbs. /1000ft.)
255
Design data
Type designation
100595
100660
100870
Figure number
18
12
19
Total wires
10
10
10
Number of conductors & AWG #
10/#20
10/#18
6/#16
4/#12
Insulation
Minimum average thickness
0.015"
0.015"
0.015"
0.020"
Spark test voltage
3000
3000
3000
4000
Inspection test voltage
1500
1500
1500
2000
Cabling
Layer 1
(a) Number of wires
2
2
2
(b) AWG #
#20
#18
#16
(c) Maximum lay
Layer 2
(a) Number of wires
8
8
4
4
(b) AWG #
#20
#18
#16
#12
(c) Maximum lay
4.00"
Sheath
Number of layers
1
2
2
Total thickness minimum
0.070"
0.110"
0.098"
Minimum OD cable
0.580"
0.645"
0.845"
Maximum OD cable
0.610"
0.675"
0.895"
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.