MIL-DTL-5898H
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are classified as
follows:
a. First article inspection (see 4.4).
b. Conformance inspection (see 4.5).
4.2 Test equipment and inspection facilities. Test and measuring equipment and inspection facilities
of sufficient accuracy, quality, and quantity to permit performance of the required inspections shall be
used. The establishment and maintenance of a calibration system to control the accuracy of the
measuring and test equipment shall be in accordance with NCSL-Z540.3 or equivalent.
4.3 Test conditions. Unless otherwise specified in the applicable test method, inspections shall be
conducted under the following environmental conditions.
a. Temperature: 15 to 35 °C.
b. Pressure:
Normal atmospheric.
c. Humidity:
Prevailing ambient (25 to 90 percent relative).
4.4 First article inspection. When required (see 6.2), first article inspection shall consist of the tests
specified in table VII.
4.5 Conformance inspection. Conformance inspection shall consist of group A (see 4.5.2) and
group B (see 4.5.3) inspections, and shall be performed on every lot of cord procured under this
specification.
4.5.1 Lot. Unless otherwise specified (see 6.2), a lot shall consist of all cord of the same PIN,
produced under essentially the same conditions, and presented for inspection at one time.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business