MIL-DTL-5898H
NCSL INTERNATIONAL
NCSL-Z540.3
-
Requirements for the Calibration of Measuring and Test
Equipment
(Copies of this document are available from https://www.ncsli.org or from NCSL International, 2995
Wilderness Place, Suite 107, Boulder, CO 80301.)
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
NEMA-WC 70
-
Standard for Non-shielded Power Cables Rated 2000 Volts or Less
for the Distribution of Electrical Energy
(Copies of these documents are available online at https://www.nema.org or from the National
Electrical Manufacturer's Association,1300 North 17th Street, Suite 1752, Rosslyn, VA 22209.)
UNDERWRITERS LABORATORIES, INCORPORATED (UL)
UL 1581
-
Reference Standard for Electrical Wires, Cables, and Flexible Cords
(Copies of these documents are available online at https://www.ul.com or from the Underwriters
Laboratories, Inc., Publication Stock, 333 Pfingsten Road, Northbrook, IL 60062-2096.)
2.4 Order of precedence. In the event of a conflict between the text of this document and the
references cited herein, the text of this document takes precedence. Nothing in this document, however,
supersedes applicable laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in
accordance with 4.4.
3.2 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or
environmentally preferable materials should be used to the maximum extent possible, provided that the
material meets or exceeds the operational and maintenance requirements, and promotes economically
advantageous life cycle costs.
3.3 Materials. The material for each part shall be as specified herein. When a definite material is not
specified, a material shall be used which enables the electrical cord to meet the requirements of this
specification. Acceptance or approval of any constituent material shall not be construed as acceptance of
this finished product.
3.3.1 Flammable, explosive or toxic materials. In normal usage, materials shall be non-flammable,
non-explosive, and nontoxic over the operating temperature range of this specification. Materials used in
construction of these cords shall not emit fumes, powder or particles visible to the naked eye when cut,
bent or otherwise manipulated during installation or normal use.
3.3.2 Coatings, jackets and other coverings. Materials used for coatings, jackets or coverings shall
not exhibit defects such as checks, cracks, splits, blisters, pimples, embedded materials or pinholes when
examined visually.