MIL-DTL-55036C
completion of group C environmental tests, conforming units shall be reinspected and shall pass all group
A inspections.
4.3.2 First article test plan and report(s). The first article test plan and test report(s) shall be as
required in the solicitation or contract.
4.4 Inspections covered by subsidiary documents. The following shall be inspected under the
applicable subsidiary documents as part of the inspection before preparation for delivery:
Item
Requirement paragraph
Copper strands
Galvanized steel-strand
3.1.1.1.1b,c
Conductor insulation
Core wrap
Inner jacket
4.5 Conformance inspection. The contractor shall perform the inspection specified in 4.4 and 4.5.1
through 4.5.4. This does not relieve the contractor of his responsibility for performing any additional
inspection necessary to control the quality of the product and to assure compliance with all specification
requirements. The Government will review and evaluate the contractor's inspection procedures and
examine the contractor's inspection records. In addition, the Government at its discretion may perform all
or any part of the specified inspection, to verify the contractor's compliance with specified requirements.
4.5.1 Group A inspection. Each length of cable (100 percent) of each lot shall be inspected for
conformance to all the inspections, and test requirements of tables II and III. Group A inspection shall be
performed in any order which is satisfactory to the Government.
9