3.9 Conductor resistance. Cable conductor direct current (dc) resistance shall not exceed the value
specified in the applicable specification sheet (see 3.1).
3.10 Thermal shock. Cables shall withstand the temperature cycles specified (see 3.1), without
cracking of the insulation and with no evidence of delamination or visible change. The insulation
shrinkage shall not be greater than that specified in the applicable specification sheet (see 3.1).
3.11 Flammability. Cables shall not convey flame along their length and shall not convey flame to
combustible materials in the vicinity when subjected to the flammability test specified in 4.6.9.
3.12 Folding. Cables shall withstand 180° transverse folding and unfolding without indicating loss of
continuity. There shall be no evidence of cracking, delamination, or fracturing, and the cables shall
subsequently meet the dielectric withstanding voltage requirement.
3.13 High-temperature aging. Cables shall withstand high-temperature aging. There shall be no
cracking or separation of the insulation, and the cables shall subsequently meet the dielectric
withstanding voltage requirement.
3.14 Flexing endurance. Cables shall exhibit no discontinuity or evidence of cracking, fracturing,
delamination, or rupturing when subjected to the flexing endurance test specified in 4.6.12.
3.15 Moisture resistance. The insulation resistance of the cables shall be not less than the value
specified in the specification sheet (see 3.1), and the insulation shall not exhibit any evidence of
delamination, when the cables are subjected to the test specified in 4.6.13.
3.16 Low pressure (maximum rated temperature). The cable insulation shall show no evidence of
shrinkage greater than .0625 inch (1.6 mm) at either end of the cable specimen, ballooning, bubbling,
voids, or insulation weight loss greater than 1 percent, when subjected to the test specified in 4.6.14.
3.17 Fungus resistance. The cables shall be fungus resistant.
3.18 Fluid immersion. The cables shall show no change in weight greater than 5 percent and no
cracking or separation of the insulation when subjected to the immersion tests specified in 4.6.16.
with the following:
a. Part or Identifying Number (PIN) (see 3.1).