MIL-DTL-24643C
TABLE IX. Sampling for group A inspections.
Units of product in lot
Number of samples
1
1
2 thru 10
2
11 thru 30
3
31 thru 90
7
91 thru 210
15
211 and over
25
4.4.3.2 Sampling for group B tests. Samples for group B tests shall be selected from each lot in accordance
with table X.
TABLE X. Sampling for group B tests.
Units of product in lot
Number of samples
8 and under
1
9 thru 30
2
31 thru 90
3
91 thru 210
4
211 and over
5
4.4.3.3 Sampling for group C tests. Samples for group C tests shall be selected in accordance with table XI.
TABLE XI. Sampling for group C tests.
Two month's production
Number of samples
(units of product)
8 and under
1
9 thru 30
2
31 thru 90
3
91 thru 210
4
211 and over
5
4.4.3.4 Sampling for group D tests. Samples for group D test shall be selected by testing the first production
run of each type and size of cable each year.
4.4.3.5 Sampling, accept/reject criteria. Material found unacceptable shall be resubmitted for re-inspection
only after all materials are re-examined or retested and all defective materials are removed or defects corrected.
Material resubmitted shall be verified 100 percent for the failing characteristic. Material found acceptable during re-
screening inspection/testing can be re-identified and released as a separate lot.
4.4.4 Group A inspections. Group A inspections as required by the specification sheet shall be performed on
samples selected in accordance with 4.4.3.1.
4.4.5 Group B inspections. Group B inspections as required by the specification sheet shall be performed on
samples selected in accordance with 4.4.3.2.