MIL-DTL-13777K
2.3 Non-Government publications. The following documents form a part of this document to the extent
specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation
or contract.
ASTM INTERNATIONAL
ASTM-A313/A313M
-
Wire Stainless Steel Spring
ASTM D1149
-
Rubber Deterioration-Surface Ozone Cracking in a Chamber
ASTM D4066
-
Nylon Injection and Extrusion Materials (PA)
(Copies of these documents are available online at https://www.astm.org or from the ASTM International,
P.O. Box C700, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.)
NCSL INTERNATIONAL
NCSL Z540.3
-
General Requirements for Calibration of Measuring and Test
Equipment
(Copies of these documents are available online at https://www.ncsli.org or from NCSL International 2995
Wilderness Place, Suite 107 Boulder, Colorado 80301-5404.)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between
the text of this document and the references cited herein (except for related specification sheets), the text
of this document takes precedence. Nothing in this document, however, supersedes applicable laws and
regulations unless a specific exemption has been obtained
3. REQUIREMENTS
3.1 Specification sheets. The individual item requirements shall be as specified herein and in accordance with
the applicable specification sheet. In the event of any conflict between the requirements of this specification
and the specification sheet, the latter shall govern.
3.2 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally
preferable materials should be used to the maximum extent possible, provided that the material meets or
exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle
costs.
3.3 Qualification. The cables furnished under this specification shall be products that are authorized by the
qualifying activity for listing on the applicable qualified products list before contract award (see 4.4 and 6.2).
3.4. Materials. The material shall be as specified and when not specifically described, shall meet the
performance characteristics specified herein.
3.5 Wire. Each wire shall consist of a conductor covered with insulating material, insulation jackets and shields
as required.
3.5.1 Conductor. Each conductor shall be composed of an assembly of coated copper strands, and when
specifically required, reinforcing steel strands (see 3.5.1.2). Conductor sizes 20 AWG through 12 AWG shall
be constructed with concentric lay conductors and shall comply with the requirements listed in table I.
Concentric lay shall be interpreted to be a central core surrounded by one or more layers of helically wound
strands. The direction of lay for the successive layers shall be alternately reversed (true concentric lay) or in
the same direction (unidirectional lay). If the direction of lay for the successive layers is the same, the pitch or
length of lay shall increase with each successive layer.