MIL-DTL-13777/4C
TABLE II. Design data Continued.
Design data
Type designation
271100S
280805
Figure number
8
9
Total wires
27
28
Number of conductors & AWG #
27/#18
#20
Insulation
Minimum average thickness
0.012"
0.015"
Spark test voltage
3000
3000
Inspection test voltage
1500
1500
Cabling
Layer 1
(a) Number of wires
3
4
(b) AWG #
#18
#20
(c) Maximum lay
Layer 2
(a) Number of wires
9
9
(b) AWG #
#18
#20
(c) Maximum lay
5.00"
Layer 3
(a) Number of wires
15
15
(b) AWG #
#18S
#20
(c) Maximum lay
Sheath
Number of layers
2
1
Total thickness minimum
0.109"
0.080"
Minimum OD cable
1.085"
0.780"
Maximum OD cable
1.115"
0.830"
Maximum weight (lbs./1000ft.)
780
See notes at end of table.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business