MIL-DTL-13777/4C
TABLE II. Design data Continued.
Design data
Type designation
211345
S221385
Figure number
1
3
Total wires
21
22
Number of conductors & AWG #
15/#18
6/#9
3/#8
4/#12
14/#16
Insulation
Minimum average thickness
0.015"
0.030"
0.060"
0.020"
0.015"
Spark test voltage
3000
4000
7500
4000
3000
Inspection test voltage
1500
2000
5000
2000
1500
Cabling
Layer 1
Filler
Filler
Layer 2
(a) Number of wires
6
6
(b) AWG #
#9
3/#8
3/#16
(c) Maximum lay
6.00"
Layer 3
(a) Number of wires
15
16
(b) AWG #
#18
4/#12
12/#16
(c) Maximum lay
9.00"
6.00"
Sheath
Number of layers
2
2
Total thickness minimum
0.156"
0.156"
Minimum OD cable
1.330"
1.360"
Maximum OD cable
1.360"
Maximum weight (lbs./1000ft.)
980
See notes at end of table.