MIL-DTL-13777/3B
1/
TABLE II. Design data Continued.
Design data
Type designation
191140
200935
Figure number.
8
10
Total wires
19
20
Number of conductors & AWG #
19/#12
13/#18
7/#15
Insulation
Minimum average thickness
0.020"
0.015"
Spark test voltage
4000
3000
Inspection test voltage
2000
1500
Cabling
Layer 1
Filler
Filler
Layer 2
(a) Number of wires
7
7
(b) AWG #
#12
#15
(c) Maximum lay
3.25"
Layer 3
(a) Number of wires
12
13
(b) AWG #
#12
#18
(c) Maximum lay
4.25"
Sheath
Number of layers
2
2
Total thickness minimum
0.098"
0.125"
Minimum OD cable
1.115"
0.920"
Maximum OD cable
1.165"
0.950"
Maximum weight (lbs/1000ft.)
540
1/ Jacketed coaxial wires
2/ 11 & 1 filler
3/ 11 W/fillers
4/ Shield applied over twisted pair of AWG #18 Maximum twist lay 3.00"
5/ Assembly with max lay of 3.00"
6/ 12 W/filler
Changes from previous issue. Marginal notations are not used in this revision to identify changes with
respect to the previous issues due to the extensiveness of the changes.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business