MIL-DTL-13777/3B
1/
TABLE II. Design data.
Design data
Type designation
160636
S160878S
161065S
Figure number
1
2
3
Total wires
16
16
16
Number of conductors & AWG #
16/#20
8/#18
8/#18S
12/#18
4/#18
Insulation
Min average thickness
0.012"
0.015"
0.015"
Spark test voltage
3000
3000
3000
Inspection test voltage
1500
1500
1500
Coaxial jacket insulation
(a) Minimum average thickness
Cabling
Layer 1
Filler
Filler
Filler
Layer 2
(a) Number of wires
5
6
4
(b) AWG #
#20
#18
#18S
(c) Maximum lay
2.0"
2.50"
3.75"
Layer 3
(a) Number of wires
11
2
8
12
(b) AWG #
#20
#18
#18S
#18
(c) Maximum lay
4.5"
5.00"
6.00"
Sheath
Number of layers
2
1
2
Total thickness min.
0.109"
0.080"
0.100"
Minimum OD cable
0.616"
0.863"
1.050"
Maximum OD cable
0.656"
0.893"
1.080"
Maximum weight (lbs./1000ft.)
538
See notes at end of table.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business