MIL-DTL-13777/3B
1/
TABLE II. Design data Continued.
Design data
Type designation
S190965S
191110S
Figure number
9
8
Total wires
19
19
Number of conductors & AWG #
8/#18S
11/#18
7/#20
12/#20S
Insulation
Minimum average thickness
0.015"
0.012"
Spark test voltage
3000
3000
Inspection test voltage
1500
1500
Cabling
Layer 1
Filler
Filler
Layer 2
(a) Number of wires
8
7
(b) AWG #
#18
#20
(c) Maximum lay
2.50"
4.0"
Layer 3
(a) Number of wires
8
3
12
(b) AWG #
#18S
#18
#20S
(c) Maximum lay
5.00"
8.0"
Sheath
Number of layers
1
2
Total thickness min
0.080"
0.140"
Minimum OD cable
0.950"
1.080"
Maximum OD cable
0.980"
1.140"
See notes at end of table.