MIL-DTL-13777/3B
1/
TABLE II. Design data Continued.
Design data
6/
Type designation
180675
180848
S190875
Figure number
6
7
8
Total wires
18
18
19
Number of conductors & AWG #
18/#20
14/#18
4/#16
19/#18
Insulation
Minimum average thickness
0.015"
0.015"
0.015"
Spark test voltage
3000
3000
3000
Inspection test voltage
1500
1500
1500
Cabling
Layer 1
Filler
Filler
Filler
Layer 2
(a) Number of wires
6
2
4
7
(b) AWG #
#20
#18
#16
#18
(c) Maximum lay
Layer 3
(a) Number of wires
12
12
(b) AWG #
#20
#18
#18
(c) Maximum lay
5.00"
Sheath
Number of layers
1
2
1
Total thickness minimum
0.080"
0.098"
0.094"
Minimum OD cable
0.650"
0.823"
0.850"
Maximum OD cable
0.700"
0.873"
0.900"
See notes at end of table.