MIL-DTL-13777/1C
TABLE III. Design data Continued.
Type designation
S041886
041210
050502
Figure number
3
3
4
Total wires
4
4
5
No. of conductors & AWG #
4/#-0
3/#4
1/#8
5/#18
Insulation
Min average thickness
0.075"
0.060"
0.015"
Spark test voltage
7500
5000
3000
Inspection test voltage
5000
2500
1500
Cabling
Layer 1
Filler
Filler
Filler
Layer 2
(a) Number of wires
4
4
5
(b) AWG #
#1-0
3/#4
1/#8
#18
(c) Maximum lay
12.00"
8.00"
Sheath
Number of layers
2
2
1
Total thickness min
0.172"
0.125
0.070"
Minimum OD cable
1.886"
1.180"
0.487"
Maximum OD cable
1.916"
1.240"
0.517"
1/ An open cotton braid separator may be substituted over this cable assembly and included in the total
sheath thickness (Type 031355).
2/ Cold Bend Torque 30 Ft/lbs.