MIL-DTL-13777/1C
TABLE III. Design data Continued.
Type designation
040500
040560
040635S
040675
040695
Figure number
3
3
3
3
3
Total wires
4
4
4
4
4
Number of conductors & AWG #
4/#16
4/#14
4/#18S
4/#12
4/#10
Insulation
Min average thickness
0.015"
0.015"
0.015"
0.015"
0.015"
Spark test voltage
3000
3000
3000
3000
4000
Inspection test voltage
1500
1500
1500
1500
2000
Cabling
Layer 1
Filler
Filler
Filler
Filler
Filler
Layer 2
(a) Number of wires
4
4
4
4
4
(b) AWG #
#16
#14
#18S
#12
#10
(c) Maximum lay
4.00"
4.00"
4.00"
4.00"
Sheath
Number of layers
1
1
1
1
1
Total thickness min
0.078"
0.080"
0.093"
0.094"
0.090"
Minimum OD cable
0.475"
0.530"
0.620"
0.625"
0.680"
Maximum OD cable
0.525"
0.590"
0.650"
0.688"
0.710"
Maximum Wt.(lbs./1000ft.)
400
2/
Type designation
040870
041065
041135
041215
Figure number
3
3
3
3
Total wires
4
4
4
4
Number of conductors & AWG #
4/#8
4/#8
3/#6
1/#8
4/#6
Insulation
Min average thickness
0.040"
0.060"
0.060"
0.060"
Spark test voltage
4000
4000
4000
7500
Inspection test voltage
2000
2000
2000
2500
Cabling
Layer 1
Filler
Filler
Filler
Layer 2
(a) Number of wires
34
4
4
4
(b) AWG #
#8
#8
3/#6
1/#8
#6
(c) Maximum lay
6.00"
5.50"
7.00"
8.00"
Sheath
Number of layers
2
2
2
2
Total thickness min
0.094"
0.141"
0.141"
0.156"
Minimum OD cable
0.850"
1.040"
1.100"
1.190"
Maximum OD cable
0.890"
1.090"
1.170"
1.240"
Maximum Wt.(lbs/1000ft.)
490
See notes at the end of table.
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business