INCH-POUND
MIL-DTL-49104C
9 November 2011
SUPERSEDING
MIL-DTL-49104B
16 July 2007
DETAIL SPECIFICATION
CABLE, TELEPHONE WD-1A/TT (FIELD WIRE, PARALLEL PAIR)
Inactive for new design after 16 June 1997.
This specification is approved for use by all Departments
and Agencies of the Department of Defense.
1. SCOPE
1.1 Scope. This specification covers stranded conductor, polyethylene insulated, parallel lay field
telephone cable. Each conductor consists of seven strands: four of copper and three of steel.
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this
specification. This section does not include documents cited in other sections of this specification or
recommended for additional information or as examples. While every effort has been made to ensure the
completeness of this list, document users are cautioned that they must meet all specified requirements of
documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed.
2.2 Government documents.
2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and
handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the
issues of these documents are those cited in the solicitation or contract.
FEDERAL SPECIFICATION
L-P-390
-
Plastic, Molding and Extrusion Material, Polyethylene and
Copolymers (Low, Medium and High Density)
Comments, suggestions, or questions on this document should be addressed to DLA Land and Maritime,
ATTN: VAI, P.O. Box 3990, Columbus, OH 43218-3990, or email to WireCable@dla.mil. Since contact
information can change, you may want to verify the currency of this address information using the ASSIST
Online database at https://assist.daps.dla.mil.
AMSC N/A
FSC 6145
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business