MIL-DTL-3432J
INSULATED CABLE ENGINEERS ASSOCIATION (ICEA)
ICEA-T-28-562
-
Test Method for Measurement of Hot Creep of Polymeric Insulations
(Copies of this document are available from https://www.icea.net or from Insulated Cable Engineers Association,
P.O. Box 1568, Carrollton, GA 30112.)
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO)
ISO 10012
-
Equipment, Quality Assurance Requirements for Measuring - Part 1
Metrological Confirmation System for Measuring Equipment
(Copies of this document are available from https://www.iso.ch or from International Organization for Standardization
nd
th
American National Standards Institute, 11 West 42 Street, 13 Floor, New York, NY10036.)
NATIONAL CONFERENCE OF STANDARDS LABORATORIES (NCSL)
NCSL Z540.3
-
General Requirements for Calibration of Measuring and Test Equipment
(Copies of this document are available from https://www.ncsli.org or from National Conference of Standards
Laboratories (NCSL), 2995 Wilderness Place, Suite 107, Boulder, CO 80301-5404.)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict
between the text of this document and the references cited herein, the text of this document takes
precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Materials. Materials shall be specified herein. Acceptance or approval of any constituent material shall not be
construed as a guaranty of acceptance of the product. When a definite material is not specified, a material shall be
used which will enable the wire and cable to meet the requirements of this specification. All materials shall be fungus
resistant in accordance with ASTM G21.
3.1.1 Wire strands.
3.1.1.1 Copper strands. The strands comprising the conductor, uninsulated ground wires (see 6.3.4), and braided
shields, shall be soft, drawn, or annealed wire conforming to the applicable requirements of A-A-59551.
3.1.2 Insulating and jacketing compounds. The insulating and jacketing compounds shall be as specified in table
III, as indicated by the application of the cable (see table II).