TABLE III-B. Details of aluminum conductors (soft metric conversion).
Cross-sectional area
Stranding
Allowable
Nominal
Diameter of
Max
(mm2)
Size
(no. of
no. of
Tensile
dia. of
stranded conductor
resistance
Elongation
desig-
strands X
missing
strength
individual
(ohms/km
(%, Min)
Nominal
Min
Max
(n/mm2)
nation
AWG of
strands
strands
Minimum
@ 20 °C)
1/
(mm)
(mm)
strands)
(Max)
(mm) 1/
8
8.39
7.98
41x24
0
0.0511
3.81
4.06
3.586
158-241
1
6
14.33
13.62
70X24
0
0.0511
5.11
5.36
2.103
158-241
1
4
21.90
20.82
107x24
0
0.0511
6.30
6.65
1.401
158-241
1
2
34.39
32.31
168x24
2
0.0511
8.00
8.38
0.879
158-241
1
1
44.83
42.24
219x24
2
0.0511
8.97
9.35
0.702
158-241
1
01
53.02
49.83
259x24
3
0.0511
10.2
10.6
0.554
158-241
1
02
68.37
64.43
334x24
3
0.0511
11.5
12.1
0.436
158-241
1
03
87.41
82.34
427x24
4
0.0511
13.0
13.6
0.358
158-241
1
04
107.07
100.83
523x24
4
0.0511
14.3
14.9
0.279
158-241
1
1/ Nominal values are for information only. Nominal values are not requirements.
THIS SOFT METRIC CONVERSION TABLE III-B PROVIDES A CROSS-REFERENCE TO TABLE II-B.
FOR INFORMATION ONLY
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business