MIL-DTL-27072E
3.3.4 Binder tape. Where binder tape is specified in the applicable specification sheet, the tape shall be
one of the following materials:
a. Polyethylene terephthalate film conforming to MIL-I-631, type G, in thickness of .001 inch
(.025 mm) minimum.
b. PVC film conforming to MIL-I-631, type F, grade A, in thickness of .005 to .010 inch
(.013 to .254 mm)
c.
PE film conforming to ASTM-D4796, class II, grade 4, in thickness of .005 to .010 inch
(.013 to .254 mm).
d. Polyester
3.3.4.1 Optional use of binder tape. When binder tape is not specified on a specification sheet,
binder tape may be applied at the manufacturer's option. If used, the binder tape shall be one of the
materials specified in 3.3.4.
3.3.5 Overall shielding. Where tinned copper strands are specified (see table I), the strands shall
conform to ASTM-B33 before shielding. Where silver-coated copper strands are specified (see table I),
the strands shall conform to ASTM-B298 before shielding.
3.3.6 Component jackets. When construction includes jacketed components (see 3.5.3), the jackets
shall be one of the following materials:
a. Polyamide in accordance with ASTM-D4066, type PA622, grade E22.
b. PVC in accordance with sheath PVC requirements of 3.3.7a.
3.3.7 Cable sheaths. Cable sheaths shall be one of the following materials:
b. PE in accordance with ASTM-D4796, class III, grade 2.
c.
FEP in accordance with ASTM-D2116.
d. PTFE in accordance with ASTM-D4894.
3.3.7.1 Physical properties. Physical properties of the sheath shall be in accordance with table V.
7