MIL-DTL-27072E
3.5.3.3 Dimensions. Dimensions of component jackets shall be specified in table VIII. The average
jacket thickness shall be not less than that shown in table VIII. The minimum wall thickness at any cross
section shall be not less than 70% of the average wall thickness at that cross section.
1/
TABLE VIII. Minimum average jacket wall thickness.
Diameter of component
Diameter of component
Jacket material
under jacket inch (mm)
under jacket inch (mm)
inch (mm)
.000 (.00) through 2.54
.000 (.00) through .100
.005 (.13)
.012 (.30)
(64.52)
(2.54)
2.57 (65.28) through 3.17
.101 (2.57) through .125
.007 (.18)
.015 (.38)
(80.52)
(3.18)
3.20 (81.28) through 5.08
.126 (3.20) through .200
.007 (.18)
.015 (.38)
(129.03)
(5.08)
5.11 (129.79) through
.201 (5.11) through .250
.008 (.20)
.015 (.38)
6.35 (161.29)
(6.35)
6.38 (162.05) through
.251 (6.38) through .500
-
.020 (.51)
12.7 (322.58)
(12.70)
12.7 (322.58) through
.501 (12.73) through .750
-
.030 (.76)
19.0 (482.60)
(19.05)
19.1 (485.14) through
.751 (19.08) through
-
.040 (1.02)
25.4 (645.16)
1.000 (25.40)
1/ Dimensions are in inches.
Metric equivalents are given for information only.
3.5.4 Final cabling. The cabling of wires, components, or combinations thereof, and fillers, if
applicable, shall be accomplished such that there is no residual twist left in the individual wires or
components. The length of lay shall be between 8 and 16 times the pitch diameter of the particular layer.
3.5.4.1 Binder tapes. Binder tapes may be used in the final cabling process. When binder tapes are
used, the tapes shall be specified in 3.3.4 and shall be applied with a minimum overlap of 25%.
with basic wire designated D or E (see table II), the binder tape and filler material, if used in the
construction, shall have a temperature rating equivalent to that of the basic wire.
3.5.4.3 Overall shielding. When specified (see applicable specification sheet), an overall shield shall
be applied over the complete cable core prior to application of the cable sheath. Shielding construction
3.5.5 Sheaths. Sheaths shall be centered over the cable core. Sheaths of materials designated A,
B, and D (see table V) shall be extruded directly over the cabled components or overall shield or binder
tape, if present. Sheath materials designated E (see table V) shall be either extruded or tape wrapped
directly over the cable components or overall shield or binder tape, if present.
3.5.5.1 Sheath wall thickness. The average sheath wall thickness shall be not less than the values
specified in table IX. The minimum wall thickness at any cross section shall be not less than 70 percent
of the average wall thickness at that cross section.