MIL-DTL-27072/66D
REQUIREMENTS:
Design and construction:
See figure 1.
Number of conductors:
7
200 °C
Temperature rating:
Component:
Basic wire:
SAE-AS22759/9-22* (formerly M16878/5BFE***) or NEMA
HP3-EEWBFE* (formerlyM16878/22BFE***)(See table I.)
Conductor:
Silver-coated copper
Primary insulation:
Polytetrafluoroethylene
Colors:
Black
Blue
Brown
Green
Red
White
Yellow
Jacket over Insulation:
Not applicable
Filler:
Not applicable
Cabling:
Core:
Number of conductors:
1
Pitch or lay:
Pull in straight
First layer:
Number of conductors:
6
Pitch or lay:
2.75 inches maximum
Binder tape material:
Polytetrafluoroethylene
Shield:
Material:
Silver-coated copper
Gauge:
36 AWG
Braid angle:
20 to 40 degrees
Jacket undershield:
Not applicable
Sheath:
Material:
Fluorinated ethylene propylene
Wall thickness:
.015 inch nominal
Tensile strength:
In accordance with MIL-DTL-27072
Ultimate elongation:
In accordance with MIL-DTL-27072
Accelerated aging:
Not applicable
Color:
See MIL-DTL-27072
Finished cable:
See table I
Cold bend:
Mandrel size in accordance with MIL-DTL-27072
Dielectric withstanding voltage:
3,000 V rms
Conductor resistance:
In accordance with basic specification
2