MIL-DTL-24643/18F
Overall shield to overall shield (Type LSMSCS only)
200
Insulation resistance (megohms/1000 feet, min.)
Conductor to conductor
500
Conductor to shield (Type LSMSCS only)
500
Overall shield to overall shield (Type LSMSCS only)
100
Conductor continuity
No failure
Shield continuity (Type LSMSCS only)
No failure
Group A:
Visual and dimensional
No failure
Watertightness (see MIL-DTL-24643 for limits of water leakage)
No failure
Abrasion resistance (scrapes min.)
No damage
Crack resistance
No damage
Group B:
Cold bending cable
No failure
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Drip (95±1 °C)
Zero
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
Elongation (percent, min.)
150
Jacket (cable)
Tensile strength (lb/in2, min.)
1300
Elongation (percent, min.)
160
Tear (lb/in thickness, min.)
35
Gas flame (1 hour)
No failure
NOTE: Type LSMSCS only, shields not grounded during test.
Group C:
Physicals (aged) air oven
Jacket (cable)
Tensile strength (percent of unaged, min.)
60
Elongation (percent of unaged, min.)
60
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business