MIL-DTL-17/211A
Flame propagation: Applicable.
Acid gas generation: 2.0 percent, maximum.
Halogen content: 0.2 percent, maximum.
Immersion test:
Tensile strength, percent of unaged minimum: 50.
Elongation, percent of unaged minimum: 50.
Smoke index: 25 maximum.
Toxicity index: 5 maximum.
Durometer hardness (type A) 80 minimum.
Weathering: Applicable.
Abrasion resistance: 75 cycles minimum (jacket only).
Tear strength: 35 pounds per inch.
Heat distortion: 30 percent maximum.
Physical tests on unaged jacket:
Tensile strength: 1,300 psi, minimum.
Elongation: 160 percent, minimum.
Physical tests on aged jacket:
Air oven:
Tensile strength, percent minimum: 60.
Elongation: percent minimum: 60.
Hot oil immersion:
Tensile strength, percent minimum: 50.
Elongation, percent minimum: 50.
Tensile strength and elongation: 1,300psi, 160 percent minimum.
Weight: 12.5 Lbs/100 ft, maximum.
Electrical:
Spark test: 5,000 Vrms, +25 percent, -0 percent.
Voltage withstanding: 10,000 V rms, minimum.
Insulation resistance: Not applicable to M17/211-00001 and M17/211-00002.
Applicable to M17/211-00003 and M17211-00004 only:
300,000 megohms, minimum per 1,000 feet (center conductor to outer conductor) at 1,000 V dc.
1,500,000 megohms, minimum per 200 feet (center conductor to outer conductor) at 1,000 V dc.
10 megohms, minimum per 1,000 feet (outer conductor to jacket) at 500 V dc.
50 megohms, minimum per 200 feet (outer conductor to jacket) at 500 V dc.