MIL-DTL-17/210A
Immersion test:
Tensile strength, percent of unaged minimum: 50.
Elongation, percent of unaged minimum: 50.
Smoke index: 25 maximum.
Toxicity index: 5 maximum.
Durometer hardness: (Type A) 80 minimum.
Weathering: Applicable.
Abrasion resistance: 75 cycles, minimum (jacket only).
Tear strength: 35 pounds per inch minimum.
Heat distortion: 30 percent maximum distortion.
Physical tests on unaged jacket:
Tensile strength: 1,300 psi, minimum.
Elongation: 160 percent minimum.
Physical tests on aged jacket:
Air oven:
Tensile strength, percent minimum: 60.
Elongatin, percent minimum: 60.
Hot oil immersion:
Tensile strength, percent minimum: 50.
Elongation, percent minimum: 50.
Tensile strength and elongation: 1,300 psi, 160 percent minimum.
Weight: 57.2 pounds per 100 feet, maximum.
Electrical:
Spark test: 8,000 V rms, minimum.
Voltage withstanding: 22,000 V rms, minimum.
Insulation resistance: Not applicable.
Corona extinction voltage: 11,000 V rms, minimum.
Characteristic impedance: 50 ohms ± 2.
Attenuation: See figure 2.
3