MIL-DTL-17/192D
Engineering notes: This cable is useful in general purpose applications, medium low temperature
applications. (See connector series "N" and "SC" in accordance with MIL-PRF-39012.) These cables
were redesigned to meet the vertical flame test. A water blocked cable option has also been included.
REQUIREMENTS
Dimensions, configuration, and description: See figure 1 and table I.
Environmental and mechanical:
Visual and mechanical examination: Applicable.
Out-of-roundness: Applicable.
Eccentricity: 10 percent, maximum.
Adhesion of conductors:
Inner conductor to core: 7 pounds, minimum; 70 pounds, maximum.
Aging stability: +98șC +2șC.
Stress crack resistance: Not applicable.
Outer conductor integrity: Not applicable.
Cold bend: -30șC +2șC.
Dimensional stability: +85°C ± 2°C.
Inner conductor from core: .125 inch, maximum.
Inner conductor from jacket: .250 inch, maximum.
Temperature stabilization: (Applicable to M17/192-00002 cable only). 1/
Temperature cycle at -28șC within 0șC and -5șC, for 24 hours.
Temperature cycle at +65șC within +5șC and -0șC, for 24 hours.
Contamination: Not applicable.
Bendability: Not applicable.
Flame propagation: Applicable.
Acid gas generation: 2.0 percent, maximum.
1/ The cable (1,000 feet) to be treated shall be wound on a spool having a 12 inch minimum barrel
diameter before, during and after cycling. The temperature cycling shall be repeated 3 times.
The time between cycling shall not exceed 30 minutes. This cable must be able to pass the
dimensional stability test following temperature cycling.