MIL-DTL-17/134D
Flame propagation: Applicable. Applicable to M17/ 134-00003 and M17/ 134-00004.
Acid gas generation: 2.0 percent, maximum. Applicable to M17/ 134-00003 and M17/ 134-00004.
Halogen content: 0.2 percent, maximum. Applicable to M17/ 134-00003 and M17/ 134-00004.
Immersion test: Applicable to M17/ 134-00003 and M17/ 134-00004.
Tensile strength, percent of unaged minimum: 50. Applicable to M17/ 134-00003 and
M17/ 134-00004.
Elongation, percent of unaged minimum: 50. Applicable to M17/ 134-00003 and M17/ 134-00004.
Smoke index: 25 maximum. Applicable to M17/ 134-00003 and M17/ 134-00004.
Toxicity index: 5 maximum. Applicable to M17/ 134-00003 and M17/ 134-00004.
Durometer hardness: (type A) 80 minimum. Applicable to M17/ 134-00003 and M17/ 134-00004.
Weathering: Applicable to M17/ 134-00003 and M17/ 134-00004.
Abrasion resistance: 75 cycles minimum (jacket only). Applicable to M17/ 134-00003 and
M17/ 134-00004.
Tear strength: 35 pounds per inch minimum. Applicable to M17/ 134-00003 and M17/ 134-00004.
Heat distortion: 30 percent maximum distortion. Applicable to M17/ 134-00003 and M17/ 134-00004.
Physical tests on unaged jacket:
Tensile strength: 1,300 psi, minimum. Applicable to M17/ 134-00003 and M17/ 134-00004.
Elongation: 160 percent, minimum. Applicable to M17/ 134-00003 and M17/ 134-00004.
Physical tests on aged jacket: Applicable to M17/ 134-00003 and M17/ 134-00004.
Air oven:
Tensile strength, percent minimum: 60.
Elongation, percent minimum: 60.
Hot oil immersion: Applicable to M17/ 134-00003 and M17/ 134-00004.
Tensile strength, percent minimum: 50.
Elongation, percent minimum: 50.
Tensile strength and elongation: 1,300 psi, 160 percent, minimum. Applicable to M17/ 134-00003
and M17/ 134-00004.
Weight: 4.5 pounds per 100 feet, max (M17/134-00001 and 00002).
5 pounds per 100 feet, max (M17/134-00003 and 00004).
4