MIL-DTL-17/134D
Inner conductor properties:
DC resistance (maximum at 20°C): 1.05 ohms per 100 feet.
Elongation: 25 percent, minimum.
Tensile strength: Not applicable.
Engineering note: This cable useful for non-hosing low temperature applications.
REQUIREMENTS
Dimensions, configuration, and description: See figure 1 and table I.
Environmental and mechanical:
Visual and mechanical examination:
Out-of-roundness: Not applicable.
Eccentricity: 10 percent, maximum.
Adhesion of conductors:
M17/134-0000X: 2 pounds minimum, 20 pounds maximum.
Aging stability:
+90°C ± 2°C (M17/134-00001and M17/134-00002)
+98°C ± 2°C (M17/134-00003 and M17/134-00004)
Stress crack resistance: Not applicable.
Outer conductor integrity: Not applicable.
Cold bend:
-55°C ± 2°C (M17/134-00001 and M17/134-00002)
-30°C ± 2°C (M17/134-00003 and M17/134-00004)
Dimensional stability: +85°C ± 2°C.
Inner conductor from core: .062 inch, maximum.
Inner conductor from jacket: .250 inch, maximum.
Contamination: Not applicable.
Bendability: Not applicable.
Flammability: Not applicable.
3