MIL-DTL-17/133F
ENGINEERING INFORMATION:
Continuous working voltage: 1,500 V rms, maximum.
Operating frequency: 20 GHz, maximum.
Velocity of propagation: 69.5 percent, nominal.
Power rating: See figure 2.
Operating temperature range: - 40°C to +125°C.
Inner conductor properties:
DC resistance (maximum at 20ēC): 2.57 ohms per 100 feet for class A wire.
6.57 ohms per 100 feet for class HS wire.
Elongation: 15 percent minimum for class 40 A wire.
1.0 percent minimum for class 40 HS wire.
2
Tensile strength: 90,000 Lb/in minimum for class 40 HS wire.
2
Tensile strength (outer - conductor): 35,000 pounds per inch , maximum, 40 percent elongation
minimum measured over two inches (not applicable to M17/133-RG405 through -00005) in
accordance with ASTM E8/E8M.
Engineering notes: This cable is useful in critical RF performance applications (see connector series
SMA in accordance with MIL-PRF-39012). This cable is generally manufactured in 20 - foot length.
Different lengths are available.
REQUIREMENTS:
Dimensions, configuration, and descriptions: See figure 1 and table I.
Environmental and mechanical:
Eccentricity: 8 percent, maximum.
Adhesion of conductors:
Inner conductor to core: 4 pounds minimum, 25 pounds maximum.
Outer conductor to core: 4 pounds minimum.
Aging stability: Not applicable.
Stress crack resistance: Not applicable.
5