MIL-DTL-17/133F
TABLE I. Description Continued.
Weight, per 1,000
PIN
Inner conductor
Dielectric core
Outer conductor 1/
feet (maximum)
Aluminum tubing,
diameter,
Type F-1
.0201 ±.0005 inch
.0865 +.002, -.001 inch,
M17/133-00015
8.0
diameter,
tin plated in accordance
diameter 4/
.066 ±.002 inch
with ASTM B545, .0003
inch minimum thick 3/ 7/
Copper tubing, diameter,
.0865 +.002, -.001 inch,
silver plated
Solid, silver-coated,
in accordance with
copper-clad steel,
M17/133-00016
15.8
ASTM B700, Type 2,
.0201 ±.0005 inch
Grade A or Grade D,
300µ inches, minimum
3/
.0201 ±.0005 inch
M17/133-00017
15.8
diameter 4/
Copper tubing, diameter,
.0865 +.002, -.001 inch,
Solid, silver-coated,
90/10 tin-plated
copper-clad steel,
M17/133-00018
in accordance with
15.7
.0201 ±.0005 inch
SAE AMS-P-81728,
.0003 inch thick,
minimum 2/ 3/
1/ Welded outer conductor in accordance with ASTM B447 and MIL-DTL-17 is optional.
2/ Hard outer conductor required (outer conductor after sinking on dielectric).
Tensile strength 33,000 PSI, minimum, 30 percent elongation, maximum measured over 2 inches.
3/ The outer diameter dimension is after plating.
4/ Nickel - coated, copper-clad steel wire, conforming to ASTM B559, class N 40 HS two
percent with uniform and continuous silver coating, 40 microinches minimum thick. Wire shall
be drawn to final size after plating.
5/ Tensile strength (outer conductor prior to sinking on dielectric): 35,000 PSI, maximum, 40 percent
elongation minimum measured over two inches.
6/ These PIN's are for soft outer conductor cables only.
7/ The tensile strength (outer conductor prior to sinking on dielectric) 15,000 PSI, maximum, 40 percent
elongation minimum, measured over 2 inches.
4