MIL-DTL-17/130F
Dimensional stability: +125ºC ± 5ºC.
Core to jacket: .015 inch, maximum.
Contamination: Not applicable.
Bendability: Mandrel diameter .50 inch, maximum (except dash numbers 00004 through 00007
mandrel diameter shall be .150 inch maximum). Mandrel diameter .250 inch maximum for -00008
through -00011. (Performance may degrade after being subjected to the mandrel test).
Flammability: Not applicable.
Weight: 34.4 pounds per 100 feet, maximum (M17/130-RG402, M17/130-00002, -00004, -00006).
35.1 pounds per 100 feet, maximum (M17/130-00001, M17/130-00003, -00005, -00007).
18.8 pounds per 1000 feet, maximum (M17/130-00008 and -00010).
20.5 pounds per 1000 feet, maximum (M17/130-00009 and -00011).
35.1 pounds per 1000 feet, maximum (M17/130-00012, -00013, -00014 and -00015).
Electrical:
Test frequency: 500 MHz to 20 GHz.
Spark test: Not applicable.
Voltage withstanding: 5,000 V rms, minimum.
Insulation resistance: Not applicable.
Corona extinction voltage: 1,900 V rms, minimum.
Characteristic impedance: 50 ohms ± 1.
Attenuation: See figures 2 and 3.
Structural return loss: See figure 4.
Capacitance: 29.9 pF per foot, maximum.
Capacitance stability: Not applicable.
Capacitance unbalance: Not applicable.
Transmission unbalance: Not applicable.
Phase stability: Not applicable.
Mechanically induced noise voltage: Not applicable.
Time delay: Not applicable.
PIN: See table I.
Supersession data: See table II.
9