MIL-DTL-13169E
FEDERAL STANDARD
FED-STD-228
-
Cable and Wire, Insulated; Methods of Testing
COMMERCIAL ITEM DESCRIPTION
A-A-59551
-
Wire, Electrical, Copper, (Uninsulated)
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-C-572
-
Cords, Yarns and Monofilaments Organic Synthetic Fiber
DEPARTMENT OF DEFENSE STANDARD
MIL-STD-104
-
Limits for Electrical Insulation Color
(Copies of these documents are available online at https://assist.daps.dla.mil/quicksearch/ or from the
Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-
5094.)
2.3 Non-Government publications. The following documents form a part of this document to the
extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitation or contract.
NCSL INTERNATIONAL
NCSL Z540.3
-
General Requirements for Calibration of Measuring and Test
Equipment
(Copies of these documents are available online at https://www.ncsli.org or from NCSL International,
2995 Wilderness Place, Suite 107 Boulder, Colorado 80301-5404.)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict
between the text of this document and the references cited herein, the text of this document takes
precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Material. The material for the wire shall be as specified herein. The best material commercially
available for the intended purpose shall be used when a definite material is not designated.
3.1.1 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or
environmentally preferable materials should be used to the maximum extent possible, provided that the
material meets or exceeds the operational and maintenance requirements, and promotes economically
advantageous life cycle costs.
3.1.2 Copper strands. The strands used in the manufacture of the conductor shall be tin-coated, soft
or drawn and annealed copper wire conforming to A-A-59551.
3.1.3 Separator. A separator may be used to provide free stripping of the insulation. If used, the
separator shall completely cover the conductor. The separator shall be type AR, form Y (acetate-rayon)
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business