MIL-DTL-915/8H
Sixth
- Jacket of either polychloroprene of chlorosulfonated polyethylene, black.
(See table I for thickness.). If necessary in order to meet the electrical
requirements for the completed cable, the jacket may consist of two layers
bonded together, with the inner layer consisting of synthetic rubber insulation.
Cable surface marking required.
NOTE: Manufacturer's identification tape may be omitted, at the manufacturer's option,
from all types and sizes.
TABLE I. Details.
Conductors
Overall diameter
Conductor
1/
1/
Jacket
Insulation
Lay
resistance
thickness
Type
thickness
length
Min
Number
Max
Size
per 1000 feet
and
minimum
minimum
(inch)
(inch)
(inch)
AWG
(max)
size
(inch)
(inch)
(ohms)
DSS-2
2
18 (class B)
0.020
2.0
0.050
0.370
0.390
7.36
DSS-3
2
16 (class B)
0.025
2.0
0.080
0.480
0.500
4.61
DSS-4
2
14 (class B)
0.025
2.5
0.065
0.480
0.500
2.84
TSS-2
3
18 (class B)
0.020
2.0
0.050
0.385
0.400
7.36
TSS-3
3
16 (class B)
0.025
2.5
0.070
0.480
0.500
4.61
2.84
0.500
0.480
0.055
2.5
0.025
14 (class B)
3
TSS-4
7.36
0.500
0.480
0.080
2.5
0.020
18 (class B)
4
FSS-2
4.61
0.500
0.480
0.060
2.5
0.025
16 (class B)
4
FSS-3
2.84
0.625
0.600
0.085
3.0
0.025
14 (class B)
4
FSS-4
7.36
0.625
0.600
0.085
3.0
0.020
18 (class B)
7
7SS-2
1/
Because of the compact construction necessary in order for these cables to meet the required
hydrostatic tests, centering and circularity requirements for insulation and jacket are waived,
provided that the finished cable complies with the value specified in table I for minimum
thickness of insulation and jacket and for overall cable diameter.
EXAMINATION AND TESTS:
Requirements
Basic electrical:
Conductor resistance - ohms/1000 feet at 25°C, maximum. (see table I)
Voltage withstand - volts, root mean square, minimum
Conductor to conductor (5 minutes)...................................................................................3000
Conductor to shield (5 minutes) ......................................................................................... 1000
Shield to water (5 minutes)...................................................................................................500
Insulation resistance megohms-1000 feet, minimum
Conductor to conductor ........................................................................................................ 500
Conductor to shield...............................................................................................................500
Shield to water ...................................................................................................................... 250
Group A:
2