INCH-POUND
MIL-DTL-915/8H
22 August 2002
SUPERSEDING
MIL-C-915/8G
29 September 1989
DETAIL SPECIFICATION SHEET
CABLE, POWER ELECTRICAL, 600 VOLTS, FOR OUTBOARD USE ONLY
(NOT FOR INBOARD USE), TYPES DSS, TSS, FSS AND 7SS
This specification is approved for use by all Departments and Agencies of the
Department of Defense.
The requirements for acquiring the product described herein shall consist of this specification
sheet and the issue of MIL-DTL-915 listed in that issue of the Department of Defense Index of
Specifications and Standards (DoDISS) specified in the solicitation.
REQUIREMENTS:
Qualification required.
Construction (watertight)
First
- Copper conductor, class B stranding, tin coated. (See table I for size.)
Second - Synthetic rubber insulation. (See table I for thickness.) Special identification
code applied by method 3.
Third
- The required number of conductors (see table I) cabled together with a lay
length not greater than that specified in table I. The insulated conductors shall
not adhere to one another. Rubber fillers as necessary in order to form a firm,
round assembly. Fillers in outer valleys may be extruded in order to be
integral with the belt (see fourth).
Fourth - Belt of synthetic rubber, nominal wall thickness 0.030 inch, over the
assembled conductors. Belt and fillers shall be capable of removal from the
assembly without damaging the insulation on conductors.
Fifth
- Braided shield of AWG No. 34 tin-coated copper. Braid angle of 50-degrees
minimum; coverage of 90-percent minimum.
AMSC N/A
1 of 4
FSC 6145
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.