MIL-DTL-915/6K
Group C:
Flammability inches, maximum ............................................................................................ 2
Physicals (aged)
Insulation (conductor)
Air oven
Tensile strength - percent of unaged, minimum ........................................................ 75
Elongation - percent of unaged, minimum. ............................................................... 75
Jacket (cable) (polychloroprene)
Air Oven
Tensile strength - percent of unaged, minimum ........................................................ 50
Elongation- percent of unaged, minimum ................................................................. 50
Hot oil immersion
Tensile strength - percent of unaged, minimum ........................................................ 60
Elongation - percent of unaged, minimum. ............................................................... 60
Permanence of printing (jacket) - cycles, minimum ............................................... 250
QUALIFICATION INSPECTION:
Qualification inspection shall include basic electrical, plus all of groups A, B, and C.
UNIT ORDERING LENGTH:
Size
Feet (nominal)
Type
THOF
400 and 500
500
PART OR IDENTIFYING NUMBER (PIN): The PIN consists of the letter M, the general
specification number along with the specification sheet, and a dash number representing type and
size. Refer to MIL-DTL-915 for an example.
M
915
/6-
X-X
Type and Size
Prefix for
Specification
Specification
Number
Sheet
Military
Specification
Number
Custodians:
Preparing activity:
Army MI
Navy - SH
Navy SH
(Project 6145-2317-002)
Review activities:
Army AR, CR
Navy - CG, EC
DLA - CC
3