INCH-POUND
MIL-DTL-915/6K
22 August 2002
SUPERSEDING
MIL-C-915/6J
29 September 1989
DETAIL SPECIFICATION SHEET
CABLE, POWER ELECTRICAL, 600 VOLTS, FOR OUTBOARD USE ONLY
(NOT FOR INB0ARD USE), TYPE THOF
This specification is approved for use by all Departments and Agencies of the
Department of Defense.
The requirements for acquiring the product described herein shall consist of this specification
sheet and the issue of MIL-DTL-915 listed in that issue of the Department of Defense Index of
Specifications and Standards (DoDISS) specified in the solicitation.
REQUIREMENTS:
Qualification required.
Construction (non-watertight)
First
- Copper, conductor, uncoated, (see table I for size).
Second - Separator.
Third
- Ethylene propylene rubber insulation. (see table I for wall thickness).
Standard identification code applied by method 3 or 4. A colored rubber
filled cotton tape may be used.
Fourth - Three conductors cabled together with a left-hand lay (see table I for
length of lay). Fibrous fillers shall be employed to obtain a firm, well
rounded assembly.
Fifth
- Binder tape applied helically with overlap on multiconductor cables.
Sixth
- Jacket of polychloroprene. Jacket shall be black. Cable surface marking
required.
NOTE:
For types SHOF, DHOF, FHOF, and THOF sizes not listed refer to
MIL-DTL-24643/3.
AMSC N/A
1 of 3
FSC 6145
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business