MIL-DTL-915/58F
Set - inch, maximum ................................................................................................. 3/8
Drip at 95 + 1°C ..................................................................................................... Zero
Group C:
Physicals (aged)
Insulation (conductor)
Synthetic rubber
Air Oven
Tensile strength - percent of unaged, minimum ............................... 50
Elongation - percent of unaged, minimum ....................................... 50
Cross linked polyethylene
Air oven
Tensile strength - percent of unaged, minimum ............................... 80
Elongation- percent of unaged, minimum ........................................ 80
Permanence of printing (conductor) - cycles, minimum ....................................................... 50
Permanence of printing (jacket) cycles, minimum ........................................................... 250
Cable filler removability............................................................................................ No failure
QUALIFICATION INSPECTION:
Qualification inspection shall include basic electrical, plus all of groups A, B, and C,
plus the following:
Cable aging and compatibility (125 + 5°C).................................................. No failure
Cold working (minus 54 + 2°C).................................................................... No failure
UNIT ORDERING LENGTHS:
Size
Feet (nominal)
7
1000
10
1000
14
500
19
500
24
500
30
500
37
500
PART OR IDENTIFYING NUMBER (PIN): The PIN consists of the letter M, the general
specification number along with the specification sheet, and a dash number representing type and
size. Refer to MIL-DTL-915 for an example.
M
915
/58-
X-X
Specification
Specification
Type and Size
Prefix for
Number
Sheet
Military
Specification
Number
3