MIL-DTL-915/10F
Jacket (cable)
Air oven
Tensile strength - percent of unaged, minimum............................................50
Elongation- percent of unaged, minimum.....................................................50
Hot oil immersion
Tensile strength - percent of unaged, minimum ............................... 60
Elongation - percent of unaged, minimum. ...................................... 60
Permanence of printing (jacket) - cycles, minimum.......................................................................250
Cable filler removability....................................................................................................... No failure
QUALIFICATION INSPECTION:
Qualification inspection shall include basic electrical, plus all of groups A, B, and C.
UNIT ORDERING LENGTH:
1590 feet, minimum to 1650 feet, maximum.
PART OR IDENTIFYING NUMBER (PIN): The PIN consists of the letter M, the general
specification number along with the specification sheet, and a dash number representing type and
size. Refer to MIL-DTL-915 for an example.
915
/10-
X-X
M
Specification
Specification
Type and Size
Prefix for
Number
Sheet
Military
Number
Specification
CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this revision to identify
changes with respect to the previous issue due to the extent of the changes.
Custodians:
Preparing activity:
Army MI
Navy - SH
Navy SH
(Project 6145-2317-006)
Review activities:
Army AR, CR
Navy - CG, EC
DLA - CC
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business