MIL-DTL-442G
TABLE IV. Group A inspections.
Inspection
Requirement
Verification
Resistance (type III)
Size
Joints
Separator (colors)
Breaking strength (type III)
Insulation (thickness)
Vinyl polymer compound (color)
Dielectric strength
Insulation resistance
Flexibility
Ozone resistance
Workmanship
4.3.4 Group B inspections.
4.3.4.1 Material. One reel or spool shall be selected at random as a control sample from each 200
produced, or from each month's production, whichever occurs first. Test specimens from this control
sample shall be subjected to the verifications listed in table V.
TABLE V. Group B inspections.
Inspections
Requirement
Verification
Construction
Material
Conductor
Separator (fungus)
Insulation (physical property values)
Vinyl polymer compound (fungus resistant)
4.3.4.2 Environmental. One reel or spool shall be selected at random as a control sample from each
100 produced, or from each month's production, whichever occurs first. Test specimens from this control
sample shall have passed the group A inspection specified herein, and shall be subjected to the
verifications in table VI.
TABLE VI. Environmental inspections.
Inspection
Requirement
Verification
Vinyl polymer heat resistance
Synthetic rubber compound aging
Natural rubber compound aging
4.3.4.3 Specimen lengths. Unless otherwise specified herein, the specimen shall be of the length
specified in the applicable test method.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business