MIL-DTL-3883B
TABLE IV. Group A and B inspections.
Inspection
Requirement
Verification
Group A
Group B
Visual and mechanical
-
4.5.1
X
-
Construction
3.3
4.5.1
X
-
Conductors
3.4.1
4.5.1
X
-
Yarn
3.4.2
4.5.1
X
-
Tape
3.4.3
4.5.1
X
-
Insulation
3.4.4
4.5.1
X
-
Color coding
3.4.5
4.5.1
X
-
Shield
3.4.6
4.5.1
X
-
Jacket
3.4.7
4.5.1
X
-
Outside diameter
3.4.8
4.5.1
X
-
Lengths
3.6.2
4.5.1
X
-
Sealing of cord ends
3.6.3
4.5.1
X
-
Workmanship
3.6.4
4.5.1
X
-
Electrical
-
-
X
-
Dielectric withstanding voltage
3.5.1
4.5.2.1
X
-
Insulation resistance
3.5.2
4.5.2.2
X
-
Conductor resistance
3.5.3
4.5.2.3
X
-
Capacitance
3.5.4
4.5.2.4
X
-
Physical
-
-
X
Cold bend
3.6.1
4.5.3.1
X
4.4.1.3 Specimen. A specimen is a single piece of finished cable or any part removed from the
finished cable such as conductors, separators, insulated conductors, shielded conductors, or cabled and
shielded conductors, insulations, and jacket, which is taken from a sample unit and subjected to
inspection.
4.4.2 Sampling. A random sample shall be selected from each lot in accordance with table V.
TABLE V. Inspection sample.
Accept on zero
Inspection lot
size 1/
sample size
1
1
2 to 8
2
9 to 90
3
91 to 150
12
151 to 280
19
281 to 500
21
501 to 1,200
27
1,201 to 3,200
36
3,201 to 10,000
38
10,001 to 35,000
46
1/ Lot size is based on the number of
units of product
6